通过持续脑电图(EEG)监测脑电双频指数(BIS)
该检查在持续脑电图(EEG)期间测量脑电双频指数(BIS),用于评估您的脑部活动和镇静水平,常用于麻醉或重症监护等医疗环境。
["\""]
关键信息一览
- LOINC
- 75918-3
- 简码
- BISEEG
- 别名
- Bispectral index Scre Ctx EEG
- 类别
- 生化
- 样本
- serum
- 采血管
- N/A - BIS monitoring uses proprietary forehead sensor electrodes connected to dedicated BIS monitor; no specimen container required
- 单位
- N/A
- 参考下限
- 40
- 参考上限
- 60
- 危急值范围
- 20 N/A – 70 N/A
- 是否空腹
- 否
- 适用人群
- 成人
- 性别
- all
- 年龄范围
- 18–65 岁
- 检测方法
- Bispectral Index (BIS) analysis using processed electroencephalography (EEG) signals captured from forehead-mounted sensor array. BIS algorithm applies Fourier transformation and bispectral analysis to raw EEG waveforms to compute a dimensionless numerical value representing depth of anesthesia and level of consciousness. Real-time signal processing is performed by dedicated BIS monitoring device (e.g., Medtronic BIS Vista, Covidien BIS).
- SNOMED
- 129254005
- 标本量
- N/A - BIS is a real-time physiological monitoring parameter, not a laboratory test performed on a biological specimen. Continuous EEG signal acquisition via scalp electrodes.
- 标本稳定性
- N/A - BIS values are generated in real-time and displayed continuously on the bedside monitor. Data logging intervals typically range from 1-10 seconds depending on device settings. Historical data is stored on the monitoring device and can be exported.
- 溶血上限
- 500
- 脂血上限
- 1000
- 黄疸上限
- 500
- 报告时间
- 4–24 小时
- 医嘱频率
- routine
BIS检查有什么用途?
BIS检查主要用于手术室或重症监护病房(ICU)等医疗环境,实时反馈您的大脑对麻醉或镇静的反应。它帮助医护人员调整药物,以维持安全且有效的意识水平。
BIS检查是如何进行的?
医护人员会在您的头皮上放置小型电极,以检测脑电波活动。脑电图记录这些波形后,由专门的设备进行处理,生成BIS评分——一个介于0到100之间的数值,反映您的脑部活动水平。
BIS评分代表什么?
BIS评分在60–100之间通常表示轻度镇静或清醒状态,低于60分则提示较深的镇静或无意识状态。接近0分可能表示非常深的麻醉状态。您的评分会被医疗团队持续监测和调整。
这项检查有风险或不适吗?
在放置电极的部位,您可能会感到轻微的刺痛或瘙痒,但检查过程本身是无痛的。电极会在整个手术期间或ICU住院期间保持在原位,因此您可能需要尽量保持静止。
Reference range
BIS values range from 0 (isoelectric EEG, no cortical activity) to 100 (fully awake and alert). Recommended interpretation ranges: 100-85 = awake/light sedation; 85-65 = light to moderate anesthesia (recommended surgical range); 65-40 = deep anesthesia with increasing burst suppression; 40-0 = profound hypnotic state/burst suppression to isoelectric. Target range for general anesthesia: 40-60.N/A
No fasting required. Ensure forehead skin is clean, dry, and free of oils, makeup, or excessive hair for optimal electrode contact. Remove jewelry from head/face area. Verify BIS sensor placement per manufacturer specifications (typically at forehead and temple regions). Confirm sensor impedance is within acceptable range before initiating monitoring. Review patient medications including neuromuscular blockers and agents affecting EEG (propofol, sevoflurane, midazolam, ketamine, dexmedetomidine).
Clinical interpretation
How abnormal results are interpreted and what conditions they suggest.
"
简称
"
常见问题
为什么医生要求我做这项检查?
这项检查需要多长时间?
检查过程中我会有感觉吗?